Control Manager Extender Error List

 

"101: cGetInfo: Invalid parameter"

"201: Invalid window handle"

"202: Invalid child sequence number or ID"

"203: Must specify child text"

"204: Specified parent window doesn't exist"

"211: cSendMsg: Invalid window handle"

"212: cSendMsg: Invalid message number"

"213: cSendMsg: 'wparam' is invalid"

"214: cSendMsg: 'lparam' is invalid"

"215: cSendMsg: Specified window does not exist"

"220: cRadioBtn: Cannot clear radio buttons. Set Only."

"221: Request code out of bounds"

"222: List/Combo box item number bad"

"223: Specified window has an unknown class name or style."

"224: Unable to set window hook."

"225: Unable to free system resource."

"226: Found invalid IP address."

"227: Specified window is not an IP address control."

"228: Unable to gain exclusive access to shared memory."

"229: Timed out waiting for window to respond."

"230: Window will not respond to mouse double clicks."

"231: Second parameter out of range."

"232: Found invalid datetime string. "

"233: This function is not supported by the current comctl32.dll"

"234: Unable to allocate system memory."

"235: Found an out of range date."

"236: Dates span more time than control will permit."

"237: Unable to find specified button."

"238: Specified button is either hidden or disabled."

"239: Up-Down buddy window is unknown or out of range."

"240: Second parameter must be a number."

"241: Unable to obtain application status."

"243: This control does not support item selection."

"244: Unable to determine the number of items in the control"

"245: Second parameter must be a list of numbers."

"246: Second parameter contains out of range item numbers."

"247: This List Box does not allow the selection of multiple items."

"248: This List Box does not support retrieval of item text."

"249: Second parameter must be a valid IP address."

"250: The second parameter must be a tab-delimited list of node names."

"251: Second parameter must be a date/time in standard format."

"252: Column number parameter must be greater than zero."

"253: Unable to attach to window."

"254: The second parameter must be a text string."

"255: The third parameter must be between 1 and 4."

"256: Cannot get text greater than 64K bytes long."

"257: Specified window not found."

"258: Third parameter must be -1, 0 or 1."

"259: Check boxes not found."

"260: First parameter must be Window handle or Window Id."

"261: Window for input window handle does not exist."

"262: Window for input window id does not exist."

"263: Unable to collect window's specification information."

"264: Invalid window specification."

"266: Window handle must be to a Top-level window."

"267: Raster device can not support this function."

"268: System can not obtain window bitmap."

"269: Control must be visible."

"270: Can not determine control's size and location."

"271: System error. Unable to determine module names."

"272: Third parameter must be a number."

"273: The optional thrid parameter must be between 1 and 4

"274: Unable to obtain TreeVew node text."

"275: Unable to initialize inter process communication."

"276: Unable to read or write to shared memory."

"277: Data size exceeds maximum for inter process communication."

"278: Cannot determine if window belongs to 64 bit process."

"279: Unable to start Control Manager helper module. "

"280: Function does not support 64-bit controls."

"281: Function does not support 32-bit controls."

"901: Control Manager Extender: Unknown function"